The “Automatic Station Bypass Control” module is designed to
meet the need to keep gas flowing in the event there are major
compressor problems. This control solution was developed with
reliability as the primary objective to ensure the Bypass Valve opens
when, and only when it is necessary. To achieve this objective, the
proven “Poppet Valve” is combined with a reliable, differential
pilot valve to form a stand-alone control module. The differential
pressure valve monitors the suction and discharge pressures of the
compressor station. When the differential drops below the adjustable
setpoint, pilot gas is passed to the pilot of the “poppet” valve and
control action is initiated. Utilizing the pipeline gas itself, for both
the pilot gas and power media, makes the “Automatic Station Bypass
Control” system independent of regulator and other power media failure.
The simplicity of design, utilizing minimal components, ensures the
bypass valve opens only when required. The “Rate of Drop”
(R.O.D.) calibration kit provides for accurate calibration of the trip
point, as well as, simulation of various operational failure scenarios
for testing control action.